Description
AE signal generator is a device intended for stimulation of elastic fluctuations (waves) which imitate acoustic emission signals at the object under test.
It is recommended for A-Line 32D (PCI-8E) AE systems.
- Pulse amplitude up to 300 V.
- Pulse rate range from 1 to 10 Hz.
- Possibility of setting the pulse emission time.
- Operation from battery and external power source.
- Low power consumption.
-
Characteristics
General parameters Pulse amplitude range, V10 ÷ 30Pulse amplitude accuracy (for 20 to 300 V range), %± 5Pulse rate range, Hz1 ÷ 10Pulse rate accuracy, %± 1Adjustable pulsing time, minutes1 ÷ 60Keypad and Display Number of keys4Display typeLCDViewing area, mm50x15Display format, chars24 (2x12)Weight and dimensions Size, mm155x80x30Weight, kg0.3Power Power supply voltage, V9Maximum power consumption, W0.05Environment conditions Temperature range, °C-20 to +70Maximum relative humidity at 25°C, %95 -
Application
AE signal generator can be used together with acoustic emission system in the following cases:
- Check of AE system workability;
- Calibration of acoustic emission sensors mounted at the tested object;
- Determination of spreading speed and attenuation degree of elastic vibrations in the tested object;
- Check of correct AE computation of acoustic emission sources by means of the location coordinate system just before testing.
The AE signal generator (calibrator) is included to basic equipment sets:
- The automated diagnostic complex of side frames and spring beams of freight cars;
- The acoustic emission unit for testing oil and petrol cistern pots.
AE signal generator is a device intended for stimulation of elastic fluctuations (waves) which imitate acoustic emission signals at the object under test.
It is recommended for A-Line 32D (PCI-8E) AE systems.
- Pulse amplitude up to 300 V.
- Pulse rate range from 1 to 10 Hz.
- Possibility of setting the pulse emission time.
- Operation from battery and external power source.
- Low power consumption.
General parameters | |
Pulse amplitude range, V |
10 ÷ 30 |
Pulse amplitude accuracy (for 20 to 300 V range), % |
± 5 |
Pulse rate range, Hz |
1 ÷ 10 |
Pulse rate accuracy, % |
± 1 |
Adjustable pulsing time, minutes |
1 ÷ 60 |
Keypad and Display | |
Number of keys |
4 |
Display type |
LCD |
Viewing area, mm |
50x15 |
Display format, chars |
24 (2x12) |
Weight and dimensions | |
Size, mm |
155x80x30 |
Weight, kg |
0.3 |
Power | |
Power supply voltage, V |
9 |
Maximum power consumption, W |
0.05 |
Environment conditions | |
Temperature range, °C |
-20 to +70 |
Maximum relative humidity at 25°C, % |
95 |
AE signal generator can be used together with acoustic emission system in the following cases:
- Check of AE system workability;
- Calibration of acoustic emission sensors mounted at the tested object;
- Determination of spreading speed and attenuation degree of elastic vibrations in the tested object;
- Check of correct AE computation of acoustic emission sources by means of the location coordinate system just before testing.
The AE signal generator (calibrator) is included to basic equipment sets:
- The automated diagnostic complex of side frames and spring beams of freight cars;
- The acoustic emission unit for testing oil and petrol cistern pots.