Description
Strain gauge (Two-channel tensometric measuring instrument) is a device intended for measurement of deformation of resistance strain gauges which can be caused by change of force, loading, twisting moment, pressure, weight, vibration and other mechanical and physical parameters.
Strain gauge can be used both independently and together with A-Line 32D acoustic emission (AE) system by means of signal injection into the relative system parametric input.
-
Characteristics
General parameters Number of measuring inputs2Modesensor/bridgeResistance of the strain gauge:
- sensor mode, Ω
- bridge mode, Ω120≥120Input range, mV± 10, 20, 40, 80ADC resolution, bit16Filter cut-off frequency (at -3 dB), Hz2Number of outputs1Output range, mV± 4096Gain factor50, 100, 200, 400Preset time of measurement delay time, s0 ÷ 900Interval delay time change, s10Adjustable measurement type:
- minutes
- hours
1 ÷ 59
1 ÷ 100Display typeLCDWorking temperatures range, °C-20 ÷ +50Power supplyKrona battery or
Adapter for 9 VDimensions, mm155х80х30Weight, g300 -
Application
Purpose
- Examination of the stress-strain state of the object under test;
- Measurement of actual values of pressure in the material of the object under test;
- Automation of the process of identification of the kind of defect according to the acoustic emission testing.
Strain gauge (Two-channel tensometric measuring instrument) is a device intended for measurement of deformation of resistance strain gauges which can be caused by change of force, loading, twisting moment, pressure, weight, vibration and other mechanical and physical parameters.
Strain gauge can be used both independently and together with A-Line 32D acoustic emission (AE) system by means of signal injection into the relative system parametric input.
General parameters | |
Number of measuring inputs |
2 |
Mode |
sensor/bridge |
Resistance of the strain gauge: - sensor mode, Ω - bridge mode, Ω |
120
≥120 |
Input range, mV |
± 10, 20, 40, 80 |
ADC resolution, bit |
16 |
Filter cut-off frequency (at -3 dB), Hz |
2 |
Number of outputs |
1 |
Output range, mV |
± 4096 |
Gain factor |
50, 100, 200, 400 |
Preset time of measurement delay time, s |
0 ÷ 900 |
Interval delay time change, s |
10 |
Adjustable measurement type: - minutes - hours |
1 ÷ 59 1 ÷ 100 |
Display type |
LCD |
Working temperatures range, °C |
-20 ÷ +50 |
Power supply |
Krona battery or Adapter for 9 V |
Dimensions, mm |
155х80х30 |
Weight, g |
300 |
Purpose
- Examination of the stress-strain state of the object under test;
- Measurement of actual values of pressure in the material of the object under test;
- Automation of the process of identification of the kind of defect according to the acoustic emission testing.